Patient Monitoring

SureSigns VS4

Vital signs monitor

Product number:

863283

Expand vital signs monitoring with Philips SureSigns VS4. Respond to changing patient conditions by choosing between frequent vitals and spot check mode. Prompt urgent action with QuickAlerts and simplify workflow with QuickCapture and QuickCheck tools.

Contact information

* This field is required
*

Contact details

*
*
*

Company details

*
*
*
*
*

Business details

By specifying your reason for contact, we will be able to provide you with a better service.
*
*
Features
Bright, color backlit screen

Bright, color backlit screen shows key vital signs

Large color-coded numerics clearly show key vital signs. They are visible in dark and well lit rooms. Confirmation of export records is easily seen in green.
Philips SpO2 technology

Choice of SpO₂ technologies supports diverse sensors

Philips is committed to providing excellent clinical measurements, including a choice of Philips FAST-based SpO₂ algorithm or Masimo® SET® or rainbow® SpO₂ (including certain rainbow parameters). Either choice is compatible with a wide variety of Philips sensors.

Specifications

SureSigns VS4
SureSigns VS4
Dimensions
  • 26 (10.2) x 22 (8.6) x 14.5 (5.7) Cm/in.
Weight
  • 3.1 (6.9) – exluding optional recorder Kg/lb
Screen
  • 8.4 inch SVGA TFT-AM LCD display, 800 active pixels/line; resolution: 600 active lines/frame; viewing angle ±60 degrees
Stepwise deflation pressure (Adult)
  • Diastolic: 10-245 (1.3-32.7); Systolic: 30-270 (4.0-36.0); MAP: 20-255 (2.7-34.0) mmHg/kPa
Stepwise deflation pressure (Pediatric)
  • Systolic: 30-180 (4.0-24.0); Diastolic: 10-150 (1.3-20.0); MAP: 20-160 (2.7-21.3) mmHg/kPa
Stepwise deflation pressure (Neonatal)
  • Systolic: 30-130 (4.0-17.0); Diastolic: 10-100 (1.3-13.3); MAP: 20-120 (2.7-16.0) mmHg/kPa
NBP measurement accuracy
  • Maximum standard deviation: 8 mmHg; Maximum mean error: ±5mmHg
Subsequent cuff inflation (in NBP interval mode only)
  • The subsequent inflation presssure is determined automatically, depending on the previous measurement and patient type
SpO2 measurement range
  • 0-100%; pulse rate measurement range 30-300 pbm. Accuracy depends on sensor
SpO2
  • Meets EN ISO 9919 standard
Welch Allyn Predictive Temperature
  • Probe Sites: Oral, rectal, axillary; Range 26.7-43.3°C (80-110°F); Accuracy ±0.1°C (±0.2°F) in monitoring mode
Covidien Tympanic Temperature
  • Range: 33°C-42°C (91.4°F-107.6°F) sec
  • Accuracy (overall range): ±0.2°C (±0.4°F) sec
  • Measurement response time: ≤2 sec
Covidien Tympanic Temperature
  • Equivalency modes: ear (no adjustment), oral (adjusted from ear), core (adjusted from ear), rectal (adjusted from ear)
Battery
  • Lithium ion: 10.8-11.1V (with a “202” form factor)
Data Output
  • HL7 format, via Ethernet port; serial data
Patient type
  • Adult, pediatric, neonatal