Versatile, easy-to-use Trilogy 200 provides invasive and non-invasive ventilator support for adult and pediatric patients in the home, hospital and acute-care sites. The pressure- and volume-mode ventilator has proprietary therapy algorithms, connectivity and enhanced triggering sensitivity which decreases the work of breathing. Trilogy 200 helps care teams provide quality respiratory care while meeting patients’ evolving needs.
Request contact
By clicking on the link, you will be leaving the official Royal Philips Healthcare ("Philips") website. Any links to third-party websites that may appear on this site are provided only for your convenience and in no way represent any affiliation or endorsement of the information provided on those linked websites. Philips makes no representations or warranties of any kind with regard to any third-party websites or the information contained therein.
I understandContinuous respiratory support for added freedom and mobility
Easy to use and adaptable for your patients’ changing needs
Adapting with every breath
Delivering on-demand ventilation
When sensitivity is needed most
Enhance patient mobility and care with Trilogy accessories
Continuous respiratory support for added freedom and mobility
Easy to use and adaptable for your patients’ changing needs
Adapting with every breath
Delivering on-demand ventilation
When sensitivity is needed most
Enhance patient mobility and care with Trilogy accessories
Dimensions |
|
---|---|
Weight |
|
Circuit types |
|
---|---|
Ventilation types |
|
Volume modes |
|
Pressure modes |
|
IPAP |
|
PEEP/EPAP for active circuits |
|
PEEP/EPAP for passive circuits |
|
CPAP for passive circuits |
|
Pressure support differential |
|
Apnea rate |
|
---|---|
Circuit disconnect |
|
High tidal volume |
|
Low tidal volume |
|
High minute ventilation |
|
Low minute ventilations |
|
High respiratory rate |
|
Low respiratory rate |
|
Respiratory rate |
|
---|---|
Minute ventilation |
|
Leak rate |
|
Vte/Vti |
|
Peak inspiratory flow |
|
Peak inspiratory pressure |
|
Mean airway pressure |
|
% Patient triggered breaths |
|
I:E ratio |
|
Tidal volume |
|
---|---|
Breath rate |
|
Inspiratory time |
|
Rise time |
|
Ramp start pressure |
|
Ramp length |
|
Flex |
|
Flow trigger sensitivity |
|
Flow cycle |
|
Apnea rate |
|
By clicking on the link, you will be leaving the official Royal Philips Healthcare ("Philips") website. Any links to third-party websites that may appear on this site are provided only for your convenience and in no way represent any affiliation or endorsement of the information provided on those linked websites. Philips makes no representations or warranties of any kind with regard to any third-party websites or the information contained therein.